Description
Ecg machine
Function
1)sync Collection For 12-lead Ecg, Adopt Digital Signal Processing Technology And Get High-quality Ecg Waveform Via Power Frequency Filter, Baseline Filter And Emg Filter Of Ecg Signal.
2)display Of 3/6/12-lead Ecg, Print Mode, Sensitivity, Paper Speed And Filter State, Etc. On One Screen, Convenient For Contrastively Diagnosing.
3)multiply Printing Modes And Formats, Including Auto 12x1, Auto 6x2+1, Auto 6x2+1_h, Auto 6x2, Auto 6x2_h, Auto 3x4+1, Auto 3x4+2, Rhythm 12, Rhythm 10, Rhythm 8, Rhythm 6, Manual, Etc. Trend Chart And Histogram Of P-r Interval Can Be Printed, Waveform Length Printed Can Be Adjusted, And With Time Print Function, Which Meets Different Requirements.
4)paper Speed: 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s.
5)with The Functions Of Auto-analysis And Auto-diagnosis For Routine Ecg Parameters, Provide Measurement Results And Auto-diagnosis Conclusion For Hr, P-r Interval, P Duration, Qrs Duration, T Duration, Q-t Interval, Q-tc, P Axis, Qrs Axis, T Axis, R(v5), S(v1), R(v5)+s(v1), Etc. Which Reduces The Doctor’s Burden.
6)built-in Memory Stores Up To 1000 Cases, Convenient For Case Review And Statistic.
7)multi-language Interface And Report.
8)in Optimal Dc State, Up To 10-hour Standby Time, Continuous Print More Than 3-hour, Record Up To 300 Ecg Waveform(commonly, It Is 3s Case), Which Meets The Requirements Of Visiting A Patient At Home And Body Examination.
Performance
Input Mode: Floating And Defibrillation Protection
Frequency Response: 0.05hz ~ 150hz(-3db~+0.4db)
Cmrr: >60db, >100db(add Filter)
Time Constant: ≥ 3.2s
Patient Leak Current: <10µa
Calibration Voltage: 1mv
Sensitivity: 2.5, 5, 10, 20, 40 Mm/mv ±5%, Standard Sensitivity: 10mm/mv±2%
Noise Level: ≤15µvp-p
Input Circuit Current: ≤50na
Input Impedance: ≥50mΩ
Sampling Accuracy: 12-bit
Safety Classification: Class I, Type Cf And Defibrillation-proof Applied Part
Recording Mode: Thermal Printing System
Paper Size: 210mm(w)×20m(l)
Sampling Frequency: 1000hz
Emg Interference Filter: 25hz/35hz (-3db)
Power Frequency Filter: Ac 50hz/60hz(-20db)
Paper Speed Auto: 25, 50mm/s, ±5%
Rhythm: 25, 50mm/s, ±5%
Manual: 5, 6.25, 10, 12.5, 25, 50mm/s, ±5%
Auto Record: Set Record According To Auto Record Format And Mode, Automatically Switching Leads, Measuring And Analyzing.
Rhythm Record: Set Record According To Rhythm Record Format And Mode, Automatically Measuring And Analyzing.
Manual Record: Set Record According To Record Format, Manually Switching Leads.
Measurement Parameters: Hr, P-r Interval, P Duration, Qrs Duration, T Duration, Q-t Interval, Q-tc, P Axis, Qrs Axis, T Axis, R(v5), S(v1), R(v5)+s(v1)
Power Supply Ac: 100v~240v(50/60hz) Dc: 14.8v/3500mah Rechargeable Lithium Battery
Fuse Specification: Two Ac Time Lag Fuse(φ5×20mm), T1.6al250v
Waterproof Degree: Ipx0
Working Mode: Continuous Working
Accessories
Standard:
A Lead Cable
A Limb Electrode
A Chest Electrode
A Thermal Recording Paper
A Power Cord
An Earth Wire
A User Manual
Physical Characteristic
Working Environment
Temperature: 5℃~40℃
Relative Humidity: 25%~95%(non-condensing)
Atmospheric Pressure: 700hpa~1060hpa
Transport And Storage Environment
Temperature: -40℃~+55℃
Relative Humidity: ≤95%
Atmospheric Pressure: 500hpa~1060hpa
Dimension: 340mm(l) × 320mm(w) × 85mm(h)
Weigh: 3.2kg